HN-1010/1510
Set Packet Attempts Limit
If ARQ Mode is set to 0, sets the number of times the radio will attempt to send an
unsuccessful transmission before discarding it. If ARQ Mode is set to 1, it is the
number of times every transmission will be sent, regardless of success or failure of a
given attempt. When this parameter is set to FFH , RF flow control mode is entered
for transmissions from the radio (See Section 2.3.4). This mode can be entered for
one or both radios in a point-to-point system. Using this mode in a point-to-multipoint
system will stop transmissions to all radios when any one radio has a full buffer.
Set Data Transmit Delay
When used in conjunction with the minimum data length parameter, this sets the
amount of time from the receipt of a first byte of data from the host until the radio
will transmit in transparent mode. Default is 00H which causes transmission to occur
without any delay. When a host is sending a group of data that needs to be sent
together, setting this parameter will provide time for the group of data to be sent by
the host before the radio transmits. If the length of data to be sent together is longer
than the time slot can send, the data will not be sent together but will be broken up
over multiple hops. The length of time the radio will wait is equal to the specified
value times the hop duration.
Set Slot Assignment Mode (base station only)
Sets whether the base station will assign remote transmit slots dynamically, based on
the number of remotes currently registered or whether the base station will assign
remote transmit slots statically, based on the maximum number of remotes parameter.
If static slot assignment is selected, make sure maximum number of remotes is
correctly set. Otherwise remote transmit performance will suffer as transmit time will
be reserved for remotes that may not exist. The dynamic assignment mode will
generally be preferred; however, the static assignment mode will result in a static
maximum data length parameter.
Set Base Slot Size (base station only)
Sets the amount of time allocated for transmission on each hop for the base station
time slot in 69.4μs increments, corresponding to 4 bytes per unit. Maximum value is
34H which corresponds to 208 bytes. If using a protocol mode, attempting to send a
packet with a length longer than this setting will cause the packet to be discarded.
? 2000- 2004 Cirronet ? Inc
45
M-2410-0010 Rev A
相关PDF资料
A-CCS32-Z-SM-R IC SOCKET PLCC 32POS TIN SMD
A-CCS44-G-R IC SOCKET PLCC 44POS GOLD
A-CCS44-Z-R IC SOCKET PLCC 44POS TIN
A-CCS44-Z-SM-R IC SOCKET PLCC 44POS TIN SMD
A-CCS52-Z-R IC SOCKET PLCC 52POS TIN
A-CCS68-Z-R IC SOCKET PLCC 68POS TIN
A-CCS84-Z-R IC SOCKET PLCC 84POS TIN
A-CCS84-Z-SM-R IC SOCKET PLCC 84POS TIN SMD
相关代理商/技术参数
A3200-385 制造商:Honeywell Sensing and Control 功能描述:A3200-385 FLEX HEATERS
A-320-04 制造商:Molex 功能描述:
A3200-407 制造商:Honeywell Sensing and Control 功能描述:A3200-407 FLEX HEATERS
A3200-6095 制造商:Honeywell Sensing and Control 功能描述:A3200-6095 FLEX HEATERS
A3200-6095A 制造商:Honeywell Sensing and Control 功能描述:HEATER 制造商:HONEYWELL FENWAL ELECTRONICS 功能描述:A3200-6095A HEATER
A3200-6162A 制造商:Honeywell Sensing and Control 功能描述:HEATER 制造商:HONEYWELL FENWAL ELECTRONICS 功能描述:A3200-6162A HEATER
A3200-6261A 制造商:Honeywell Sensing and Control 功能描述:HEATER 制造商:HONEYWELL FENWAL ELECTRONICS 功能描述:A3200-6261A HEATER
A32022-1 制造商:MISCELLANEOUS 功能描述: